Rittmeyer WSR3000 communication driver

Rittmeyer WSR3000 Communication Driver is intended for data connection between Reliance's runtime software and Rittmeyer WSR3000 devices connected via the WSK150 communication unit.

These are the driver's main benefits

  • Faster communication thanks to communication packet optimization
  • Using spontaneous reports for reading data of a device
  • Option to choose either the warm or cold start of the driver
  • Improved diagnostics thanks to communication packet visual display
Note Box, icon

Supported Reliance versions

The communication driver is supported in both Reliance 5 and Reliance 4.

Communication with a PLC runs in one of the following ways:

  • RS-232 serial link
  • RS-485/422 serial link

Starting up the driver

The communication driver is a DLL loaded into memory by the Reliance 4 Driver Server program, which can be launched either as a Windows service at Windows startup or as a standard application at the start of a visualization project. Information required to make a connection with devices is read from the visualization project. Communication to the devices is optimized at the start of the visualization with respect not to overload the communication lines.

Reading data

The device's data is read based on the so-called “Spontaneous Reports”. At startup, the driver establishes a connection with individual data points in the devices. The devices then send current data only in case the tag value changes.
The so-called “Forced Update Interval” can be configured for each tag. If the tag value stays the same at a specified interval, the driver sends a request for a data update which is independent of the spontaneous reports.

Detecting the loss of connection with the device

The loss of connection is detected if the communication driver doesn’t receive a valid response Nx consecutively (N represents the maximum number of failed communications). This parameter can be adjusted.

For information about the price, please contact your local distributor.

Lightbulb, icon

Tip:

Haven't found what you were looking for? Use this form to inform us about it.

Related links


Products

Reliance 5

OPC Servers

Download

Try the Reliance SCADA system right now!

Try the Reliance SCADA/HMI system on several sample visualizations.

Try the Reliance SCADA/HMI system on several sample visualizations or download the trial version installer to your computer for free.

Try the Reliance SCADA system right now Try the Reliance SCADA system right now Try the Reliance SCADA system right now